Tesla Capacitor/Overload Boxes & Tesla Guardian Controls Tesla Capacitor/overload Boxes & Tesla Guardian Controls

FREE NEXT WORKING DAY DELIVERY ON ORDERS OVER £100.00

  Guardian Controls by Tesla Submersible Pumps

Tesla Guardian ME 1E & 2E Controls Panel with microprocessor for protection and control of motor/single-phase/three-phase pump with direct start up. The main feature of this new Guardian Evolution series, completly revised, is the protection of the motor/pump against drying running without level probes, motor cos value is is controlled by the Tesla Guardian. Casing made of shock-proof and self-extinguishing thermoplastic material with two antipull plugs. Main switch. Power supply: single-phase 230v +/-5%, three-phase 400v +/-5%. Digital display with status indictions. Four models available for powers from 0.5 HP to 15 HP. Protection degree IP54. Starting Capacitor for single-phase version. Optoisolated auxiliary contact for control probes, pressure switch & float switch.

  • ON-OFF switch.
  • Overload protection.
  • Phase failure protection (three phase version).
  • Overvoltage protection.
  • Short circuit protection.
  • Protection against dry running. 

Tesla Guardian Controls UK Supplier All Pumps Direct UK

Tesla Borehole Control Equipment - Capacitor/overload Boxes

Tesla Borehole Control Equipment - Capacitor/overload Boxes

Tesla Borehole Control Equipment - Capacitor/overload Boxes
Click to enlarge image(s)
Capacitor/Overload box
4" Borehole motors
230v
For connection with Borehole motor. On/off switch and resetable overload.


Tesla Guardian ME 1E & 2E Control Panels for pumps & motors in wells & boreholes

Tesla Guardian ME 1E & 2E Control Panels for pumps & motors in wells & boreholes

Tesla Guardian ME 1E & 2E Control Panels for pumps & motors in wells & boreholes
Click to enlarge image(s)
Tesla Guardian gives dry run protection without probes in the well - the control box replaces the standard control box and monitors motor power facter. it trips out and retries at 20, 45, & 90 minute intervals to see if water level has recovered - if not it turns the power off to protect the motor. Replaces existing control box and can be wired to pressure switches "etc"

Guardian ME Control Panel
kW - 0.37-2.2
Volt - 230
Capacitor - TO SUIT
Over Load - 1-18A

Guardian 1E Control Panel
kW - 0.37-2.2
Volt - 415
Capacitor - N/A
Over Load - 1-9A

Guardian 2E Control Panel
kW - 3-7.5
Volt - 415
Capacitor - N/A
Over Load - 10-20A

TESLA SUBMESIBLE PUMPS

PRICES DO NOT INCLUDE VAT

FREE DELIVERY