Full Pump Control Panels Accessories - Pump Equipment - Control Panels

FREE DELIVERY ON ORDERS OVER £100.00

CP1SM-13A Full Control Panel for Single Pump 230vCP1SM-13A Full Control Panel for Single Pump 230v
CP2SM-13A Full Control Panel for Twin Pumps 230vCP2SM-13A Full Control Panel for Twin Pumps 230v
CPS-13A Full Control Panel for Single Pump 415vCPS-13A Full Control Panel for Single Pump 415v
CPS-13A Full Control Panel for Twin Pumps 415vCPS-13A Full Control Panel for Twin Pumps 415v
Pump Control Panel KioskPump Control Panel Kiosk
Flashing Beacon for Pump Control PanelsFlashing Beacon for Pump Control Panels
Flashing Beacon + Sound for Pump Control PanelFlashing Beacon + Sound for Pump Control Panel
Rectifier and Internal Buzzer/ Remote ConnectionRectifier and Internal Buzzer/ Remote Connection
Mac 3 Hydrocontroller Inverter Driver HCW MT 230vMac 3 Hydrocontroller Inverter Driver HCW MT 230vThe Mac 3 Hydrocontroller is used to continuously regulate the rotation speed of elctro pumps, thus ensuring a constant pressure despite varying flow. This unit can be used for water cooling.
CP1SM-13A Full Control Panel for Single Pump 230v
Click to enlarge image(s)

CP1SM-13A Full Control Panel for Single Pump 230v

Full control panel for single pump 230v comes complete with resetable overload switch, interlock main isolator, line fuses, starters with overload relays and pump run and trip indicators. 24 volt ac supply for audible warning when using third float. 
Fitted in a IP54 steel enclosure which will protect it from accidental splashes of water.
Low voltage 24 volt supply to float switches (not supplied) confirming to water regulations.
When using the three float system the top float is the high level alarm float which can operate a audible/visual indicator (optional extra) to alert there is a problem

Single panel H 400mm x W 300mm x L160mm 12kg. (Pictured)
Double panel H 500mm x W 350mm x L160mm 14.5kg

Various overloads are available to suit your requirements - 2.3-4amp/6.3-10amp/10-16amp (please advise when ordering on the coments section of the checking out page.)


CP2SM-13A Full Control Panel for Twin Pumps 230v
Click to enlarge image(s)

CP2SM-13A Full Control Panel for Twin Pumps 230v

Full control panel for double pumps 230v comes complete with resetable overload switch, interlock main isolator, line fuses, starters with overload relays and pump run and trip indicators. 24 volt ac supply for audible warning when using third float. 
Fitted in a IP54 steel enclosure which will protect it from accidental splashes of water.
Low voltage 24 volt supply to float switches (not supplied) confirming to water regulations.
When using the three float system the top float is the high level alarm float which can operate a audible/visual indicator (optional extra) to alert there is a problem

Single panel H 400mm x W 300mm x L160mm 12kg. (Pictured)
Double panel H 500mm x W 350mm x L160mm 14.5kg

Various overloads are available to suit your requirements - 2.3-4amp/6.3-10amp/10-16amp (please advise when ordering on the coments section of the checking out page.)


CPS-13A Full Control Panel for Single Pump 415v
Click to enlarge image(s)

CPS-13A Full Control Panel for Single Pump 415v

Full control panel for single pump 415v comes complete with resetable overload switch, interlock main isolator, line fuses, starters with overload relays and pump run and trip indicators. 24 volt ac supply for audible warning when using third float. 
Fitted in a IP54 steel enclosure which will protect it from accidental splashes of water.
Low voltage 24 volt supply to float switches (not supplied) confirming to water regulations.
When using the three float system the top float is the high level alarm float which can operate a audible/visual indicator (optional extra) to alert there is a problem

Single panel H 400mm x W 300mm x L160mm 12kg. (Pictured)
Double panel H 500mm x W 350mm x L160mm 14.5kg

Various overloads are available to suit your requirements - 2.3-4amp/6.3-10amp/10-16amp (please advise when ordering on the coments section of the checking out page.)


CPS-13A Full Control Panel for Twin Pumps 415v
Click to enlarge image(s)

CPS-13A Full Control Panel for Twin Pumps 415v

Full control panel for double pumps 230v comes complete with resetable overload switch, interlock main isolator, line fuses, starters with overload relays and pump run and trip indicators. 24 volt ac supply for audible warning when using third float. 
Fitted in a IP54 steel enclosure which will protect it from accidental splashes of water.
Low voltage 24 volt supply to float switches (not supplied) confirming to water regulations.
When using the three float system the top float is the high level alarm float which can operate a audible/visual indicator (optional extra) to alert there is a problem

Single panel H 400mm x W 300mm x L160mm 12kg. (Pictured)
Double panel H 500mm x W 350mm x L160mm 14.5kg

Various overloads are available to suit your requirements - 2.3-4amp/6.3-10amp/10-16amp (please advise when ordering on the coments section of the checking out page.)