Pump Control equipment - Full control panels for sewage pumps, basic pump control panels & 4" Bolehole capacitor/overload boxes
CP1SM-13A Full Control Panel for Sewage Pumps - £351.94

 |
|
| Click to enlarge image(s) |
Full control panel for single & double pumps 230v & 415v comes complete with resetable overload switch, interlock main isolator, line fuses, starters with overload relays and pump run and trip indicators. 24 volt ac supply for audible warning when using third float. Various overloads are available to suit your requirements - 2.3-4amp/6.3-10amp/10-16amp (advise when ordering)
Fitted in a IP54 steel enclosure which will protect it from accidental splashes of water.
Low voltage 24 volt supply to float switches (not supplied) confirming to water regulations.
When using the three float system the top float is the high level alarm float which can operate a audible/visual indicator (optional extra) to alert there is a problem
Single panel H 400mm x W 300mm x L160mm 12kg. (Pictured)
Double panel H 500mm x W 350mm x L160mm 14.5kg
ALL PRICES INCLUDE VAT & DELIVERY
4" Borehole motors - capacitor/overload boxes
Tesla Borehole Control Equipment - Capacitor/overload Boxes from £44.53

 |
|
| Click to enlarge image(s) |
Capacitor/Overload box
4" Borehole motors
230v
For connection with Borehole motor. On/off switch and resetable overload.
ALL PRICES INCLUDE VAT & DELIVERY
Basic Control panels & Alarms
Basic Pump Control Panel no capacitor & with capacitor fitted 230v - £140.06

 |
|
| Click to enlarge image(s) |
Basic single pump control panels come complete with a resetable overload switch which trips out when there is a problem with a pump example - pump jams on a foreign object. Fitted in a IP44 enclosure which will protect it from accidental splashes of water.
Low voltage 24volt supply to float switches (not included)conforming to water regulations.
Basic panel to suit pumps that have external capacitors.
ALL PRICES INCLUDE VAT & DELIVERY
Basic Pump Control Panel - No Capacitors fitted 415v - £147.93

 |
|
| Click to enlarge image(s) |
Basic single pump control panels come complete with a resetable overload switch which trips out when there is a problem with a pump example - pump jams on a foreign object. Fitted in a IP54 enclosure which will protect it from accidental splashes of water.
Low voltage 24volt supply to float switches (not included)conforming to water regulations.
ALL PRICES INCLUDE VAT & DELIVERY
Basic pump control panel with fitted capacitor and low level probe control - £199.63

 |
|
| Click to enlarge image(s) |
Basic single pump probe control panels come complete with a resetable overload switch which trips out when there is a problem with a pump example - pump jams on a foreign object. Fitted in a IP44 enclosure which will protect it from accidental splashes of water.
Low voltage 24volt supply to probe control switches (not included) conforming to water regulations.
Basic probe panel to suit pumps that have external capacitors but by ommiting a connection, are suitable for pumps with internal capacitors.
For wells & boreholes.
ALL PRICES INCLUDE VAT & DELIVERY
Sentinel Alarm Unit for pumping - £85.50

 |
|
| Click to enlarge image(s) |
+£8.00 delivery + £16.36 VAT
Sentinel high/low level alarm can be used for almost any application where detection of high or low level warning needs to be raised. Low voltage output for float connection (float not included) Battery back up in case of mains failure.
Tesla Guardian ME 1E & 2E Control Panels for pumps & motors in wells & boreholes

Tesla Guardian gives dry run protection without probes in the well - the control box replaces the standard control box and monitors motor power facter. it trips out and retries at 20, 45, & 90 minute intervals to see if water level has recovered - if not it turns the power off to protect the motor. Replaces existing control box and can be wired to pressure switches "etc"
Guardian ME Control Panel
kW - 0.37-2.2
Volt - 230
Capacitor - TO SUIT
Over Load - 1-18A
Guardian 1E Control Panel
kW - 0.37-2.2
Volt - 415
Capacitor - N/A
Over Load - 1-9A
Guardian 2E Control Panel
kW - 3-7.5
Volt - 415
Capacitor - N/A
Over Load - 10-20A
 Tesla Guardian ME Control Panel
|
 Tesla Guardian 1E Control Panel
|
 Tesla Guardian 2E Control Panel
|
|
Optional High Level Alarm Equipment & Extras for Pump Control Panels
Rectifier & Internal Buzzer/ Remote Connection

 |
|
| Click to enlarge image(s) |
Rectifier & Internal Buzzer/ Remote Connection
PRICE INCLUDES VAT & DELIVERY
Flashing Beacon for Pump Control Panels

 |
|
| Click to enlarge image(s) |
Flashing Beacon
If supplying a flashing beacon only, a rectifier still needs to be fitted to operate.
PRICE INCLUDES VAT & DELIVERY
Flashing Beacon + Sound for Pump Control Panel

 |
|
| Click to enlarge image(s) |
Flashing Beacon + Sound
PRICE INCLUDES VAT & DELIVERY
5.6-7.5Kw (11-16 AMP) Overload & Contactor Upgrade

 |
|
| Click to enlarge image(s) |
5.6-7.5Kw (11-16 AMP) Overload & Contactor Upgrade
PRICE INCLUDES VAT & DELIVERY
Logicflow Electronic Flowswitch for pumps
Cheap Logicflow electronic flowswitch for pumps

 |
|
| Click to enlarge image(s) |
Controls the start up and the stop of the motor of the electric pump every time a service is open or closed. Turns off the motor and save the pump in case of lack of water. Needs to work a minimum flow of water that crosses itself when a service is open. The flow may come from a water tank or directly from the water mains. In the first application the device and the higher service of the system must be placed always below the water tank (see Fig 1-3). In the second application the pressure generated by the main water supply must ensure the minimum flow up to the higher service of the system (see Fig 2-4)
Singlephase power supply voltage 230v
Acceptable voltage fluctuations +/- 10%
Frequecy 50-60 Hz
Maximum current 8A
Maximum power 1,1 Kw (1,5 HP)
Maximum working pressure 12 bar
Maximum working temperature 60 degrees C
Minimum starting flow ~1 l/min
Enclosure rating IP 65
Male connections Gc 1"
PRICES INCLUDES DELIVERY & VAT
1.5kva 110v Site transformer for pumps £68.00

 |
|
| Click to enlarge image(s) |
+ £8.00 Delivery + £13.30 VAT
30-110v dual 16amp outlet site transformer with thermal protection
Replacment Pump Cables with Gland